X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.25 293 50% ethylene glycol/PEG 8000, 0.1 M carboxylic acids mix, 0.1 M Buffer system 2 pH 7.5
Unit Cell:
a: 141.227 Å b: 65.012 Å c: 116.341 Å α: 90.00° β: 103.38° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.73 Solvent Content: 54.90
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.00 49.69 64184 3450 97.17 0.24899 0.27238 41.090
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.98 50.00 96.6 0.032 ? 21.6 3.3 ? 69187 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.98 2.05 79.3 ? ? 2.3 2.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.972 ESRF ID29
Software
Software Name Purpose Version
REFMAC refinement 5.7.0027
MOSFLM data reduction .
Aimless data scaling .
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback