X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 293 NAOAC, PEG4000, GLYCEROL, TRIS, PH 8.5, VAPOR DIFFUSION, SITTING DROP, TEMPERATURE 293K
Unit Cell:
a: 47.550 Å b: 47.940 Å c: 47.940 Å α: 76.87° β: 61.42° γ: 69.33°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.64
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.50 44.74 50788 2706 96.3 0.179 0.202 22.50
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.500 44.740 96.2 0.05800 ? 8.9000 2.900 ? 53495 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.50 1.53 94.5 ? ? 2.600 2.80 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-2 0.873 ESRF ID23-2
Software
Software Name Purpose Version
iMOSFLM data reduction .
Aimless data scaling 0.5.15
PHASER phasing .
REFMAC refinement 5.8.0131
Feedback Form
Name
Email
Institute
Feedback