X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 293 0.1 M Bis-Tris propane pH 6.5, 16% (w/v) PEG 3350, 0.2 M MgCl2
Unit Cell:
a: 101.221 Å b: 65.151 Å c: 128.533 Å α: 90.000° β: 112.810° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.19 Solvent Content: 43.93
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.3500 46.65 167978 16858 99.3600 0.1790 0.1941 18.9349
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.350 46.650 99.500 0.050 ? 14.700 3.800 ? 167978 ? ? 13.020
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.350 1.370 99.700 ? ? ? 3.600 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 0.91165 ESRF ID23-1
Software
Software Name Purpose Version
PHENIX refinement .
EDNA data collection .
XDS data reduction .
Aimless data scaling 0.5.1
PHASER phasing .
PDB_EXTRACT data extraction 3.22