X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 HLE from human blood was purchased from SERVA as a lyophilisate in the presence of sodium acetate puffer, pH 5.5. The lyophilisate was disolved in water so that the HLE concentration was 5 mg/ml (170 micromolar) and the acetate concentration 250 millimolar. 120 microliter dissolved HNE lysophilisate was mixed with 6 microliter inhibitor solution (10 mM in DMSO). 1 microliter of the resulting HLE/inhibitor mixture was mixed with 0.5 microliter reservoir solution which was composed of 20 % PEG MME 5000, 0.2 M potassium sulphate. Repeated seeding was necessary to get usable crystals. In the final seeding step the reservoir was composed of 20 % PEG MME 5000, 0.2 M sodium sulphate.
Unit Cell:
a: 204.557 Å b: 204.557 Å c: 62.155 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: H 3 2
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 54.16
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.700 45.553 13721 1046 99.99 0.1804 0.2336 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.7 45.6 99.94 0.2407 0.2407 15.40 20.7 ? 13722 ? ? 62.04
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.70 2.83 100 ? ? 1.2 21.6 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X06DA 1.0000 SLS X06DA
Software
Software Name Purpose Version
PHENIX refinement (1.12_2829: ???)
XDS data reduction .
Aimless data scaling .
PHASER phasing .