ELECTRON MICROSCOPY
Sample
Ebola virus - Mayinga, Zaire, 1976
Specimen Preperation
Sample Aggregation State
HELICAL ARRAY
Vitrification Instrument
FEI VITROBOT MARK II
Cryogen Name
ETHANE
Sample Vitrification Details
?
3D Reconstruction
Reconstruction Method
SUBTOMOGRAM AVERAGING
Number of Particles
1
Reported Resolution (Å)
7.3
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Local resolution was estimated using moving window FSC calculations. Resolution varies from 7.3 to 15.2 Angstroms.
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
?
Refinement Protocol
RIGID BODY FIT
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
Nucleoprotein model from Ebola virus nucleoprotein 1-450 was first rigid body fitted into the inner nucleoprotein densities. Densities were then subtracted, and VP24 pdb was then fit into remaining densities. All models were rigid-body fitted using UCSF Chimera.
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å
2
)
3.4
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
2000
Maximum Defocus (nm)
4500
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
81000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
VOLUME SELECTION
Amira
4
VOLUME SELECTION
TOM Toolbox
?
IMAGE ACQUISITION
SerialEM
?
CTF CORRECTION
CTFFIND
4
CTF CORRECTION
CTFPHASEFLIP
?
MODEL FITTING
UCSF Chimera
?
FINAL EULER ASSIGNMENT
AV3
?
RECONSTRUCTION
AV3
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING ONLY
CTF amplitude correction was performed during the wedge-weighted subtomogram averaging step.