X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 290 CaCl2, HEPES pH 7.5, PEG 3,350
Unit Cell:
a: 74.999 Å b: 81.724 Å c: 95.365 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 2 2 2
Crystal Properties:
Matthew's Coefficient: 2.25 Solvent Content: 45.29
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.8190 32.0950 26648 1343 99.8800 0.1781 0.2090 28.1263
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.820 50.000 99.800 0.043 ? 20.500 9.500 ? 26651 ? ? 20.300
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.820 1.850 97.700 ? ? ? 7.300 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-BM 0.979 APS 19-BM
Software
Software Name Purpose Version
PHENIX refinement 1.13rc1_2954
SCALEPACK data scaling .
PDB_EXTRACT data extraction 3.24
HKL-2000 data reduction .
MOLREP phasing .