X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 277 15% PEG3350, 0.1M Bis-tris propane pH 7.5, 0.2M NaF
Unit Cell:
a: 38.941 Å b: 82.412 Å c: 176.032 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.50 Solvent Content: 50.84
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.820 47.799 51923 2558 99.96 0.2002 0.2328 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.82 47.799 99.95 0.021 ? 12.5 2 ? 51926 ? ? 34.36
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.82 1.885 99.8 ? ? 0.97 2 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement (1.12_2829: ???)
XDS data reduction .
Aimless data scaling version 0.5.32
MOLREP phasing Vers 11.5.05