6C7Y

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 281 100mM HEPES pH 7.0, 14% (w/v) PEG8000, 100mM magnesium acetate, 2mM TCEP
Unit Cell:
a: 83.926 Å b: 83.926 Å c: 161.438 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 41 21 2
Crystal Properties:
Matthew's Coefficient: 3.09 Solvent Content: 60.17
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.4990 40.6130 20702 1995 99.9300 0.2100 0.2414 86.2543
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.500 40.613 99.900 0.113 ? 15.770 8.268 ? 20768 ? ? 54.940
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.500 2.560 99.800 ? ? 1.660 8.419 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 77 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.11.1_2575
PDB_EXTRACT data extraction 3.24
XDS data reduction .
XSCALE data scaling .
PHENIX phasing .