X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 281 Protein was at 10 mg/mL and was set up in 250 plus 250 nL drops with a reservoir of 50 mM Tris pH 8.0, 2.8 M ammonium sulfate at 8C
Unit Cell:
a: 42.311 Å b: 41.425 Å c: 72.424 Å α: 90.00° β: 104.51° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.10 Solvent Content: 41.37
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.50 41.4 37027 1947 99.74 0.15533 0.18757 14.567
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.50 41.4 99.7 0.087 ? 18.2 7.3 ? 38990 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.50 1.53 94.3 ? ? 2.5 6.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.950100 Australian Synchrotron MX1
Software
Software Name Purpose Version
REFMAC refinement 5.8.0189
XDS data reduction .
Aimless data scaling .
PHASER phasing .