X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.3 294 22-28% PEG 3350, 0.2M Potassium Nitrate, 0.1M Bis-Tris-Propane pH 7.3
Unit Cell:
a: 68.185 Å b: 182.599 Å c: 76.838 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.73 Solvent Content: 54.88
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.100 39.246 28423 1417 99.89 0.1878 0.2284 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.10 39.09 99.4 0.03453 ? 12.5 7.2 ? 31731 ? ? 24.0655815872
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.05 2.18 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement (1.11.1_2575: ???)
iMOSFLM data reduction .
Aimless data scaling .
PHASER phasing .