X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.8 293 0.1 M BTP pH 8.8, 0.2 M Na-Iodide, 14 % w/v PEG 3350 and 2 % w/v PEG 20000
Unit Cell:
a: 66.805 Å b: 74.863 Å c: 96.276 Å α: 94.22° β: 97.88° γ: 90.16°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.28 Solvent Content: 46.08
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.600 38.815 55986 2842 98.81 0.1959 0.2477 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.60 38.815 98.8 0.139 ? 10.5 10.5 ? 55986 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.60 2.74 98.2 ? ? 3.9 3.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.9_1692
XDS data reduction .
SCALA data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback