X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.6 291.15 0.2M Ammonium sulfate, 0.1M Sodium acetate trihydrate pH 4.6, 25% PEG4000
Unit Cell:
a: 59.366 Å b: 59.628 Å c: 215.278 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 2 21
Crystal Properties:
Matthew's Coefficient: 2.04 Solvent Content: 35.73
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.900 42.070 60987 3113 99.46 0.2483 0.2683 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.9 45.74 99.6 0.088 ? 9.9 6.0 ? 61049 ? ? 30.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.94 100 ? ? 2.0 5.7 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.9537 Australian Synchrotron MX1
Software
Software Name Purpose Version
PHENIX refinement (1.12_2829: ???)
iMOSFLM data reduction .
Aimless data scaling .
PHASER phasing .
Feedback Form