X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 PEG400, Potassium chloride, Calcium chloride, Sodium cacodylate
Unit Cell:
a: 125.121 Å b: 121.080 Å c: 185.119 Å α: 90.000° β: 101.960° γ: 90.000°
Symmetry:
Space Group: I 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.29 Solvent Content: 46.37
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.4700 55.2500 430890 22662 99.3800 0.1505 0.1752 13.3740
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.45 112.84 99.2 0.090 ? 7.4 3.4 ? 473154 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.45 1.47 95.9 ? ? 1.6 3.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.97241 ESRF ID29
Software
Software Name Purpose Version
REFMAC refinement 5.8.0258
PDB_EXTRACT data extraction 3.22
XDS data reduction .
MOLREP phasing .
Aimless data scaling .