X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 20-25 % Tacsimate (pH 7.0), 2 % PEG 3350, and 100 mM HEPES (pH 7.0)
Unit Cell:
a: 70.147 Å b: 70.147 Å c: 217.458 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 64 2 2
Crystal Properties:
Matthew's Coefficient: 2.96 Solvent Content: 58.49
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.00 19.907 21144 1053 99.52 0.23579 0.25172 50.384
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 20 99.9 ? ? 65.9 20.7 ? 22298 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.00 2.07 100.0 ? ? 4.9 20 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSRRC BEAMLINE BL13B1 1.0 NSRRC BL13B1
Software
Software Name Purpose Version
REFMAC refinement 5.8.0158
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .