5XIQ

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 293 10%(w/v) PEG 4K, 20%(v/v) glycerol, 0.03M of each divalent cation and 0.1M MES/imidazole
Unit Cell:
a: 76.852 Å b: 90.898 Å c: 92.869 Å α: 89.860° β: 80.920° γ: 75.820°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 54.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.1900 40.3200 114158 6057 97.3900 0.1676 0.2069 44.4140
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.19 50.000 98.300 0.091 ? 7.400 4.000 ? 120215 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.200 2.240 97.500 ? ? ? 3.700 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM14 0.95373 ESRF BM14
Software
Software Name Purpose Version
MxCuBE data reduction .
HKL-2000 data scaling .
REFMAC refinement 5.7.0029
PDB_EXTRACT data extraction 3.22
PHASER phasing .