X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 10%(w/v) PEG-8000, 20mM Tris-HCl, pH 7.0, and 0.2M MgCl2
Unit Cell:
a: 86.202 Å b: 86.202 Å c: 36.287 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 61
Crystal Properties:
Matthew's Coefficient: 2.03 Solvent Content: 44.87
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD FREE R-VALUE 1.804 24.884 14372 688 99.92 0.1744 0.2003 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.8 50 100 0.063 ? 35.98 9.9 ? 14399 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.80 1.83 100 ? ? 3.7 9.7 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL19U1 0.9792 SSRF BL19U1
Software
Software Name Purpose Version
PHENIX refinement (1.11.1_2575: ???)
HKL-3000 data reduction .
HKL-3000 data scaling .
PHENIX phasing .
Feedback Form
Name
Email
Institute
Feedback