X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 291 0.1 M BICINE/TRIS BUFFER PH8.5 INCLUDING 10% (V/V) PEG 4000, 25% (V/V) ETHYLENE GLYCOL, 150 mM D,L-LYSINE, 10 mM MENADIONE
Unit Cell:
a: 72.804 Å b: 113.570 Å c: 129.781 Å α: 90.00° β: 91.02° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 3.07 Solvent Content: 59.88
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? FREE R-VALUE 2.150 48.867 105123 5241 91.69 0.2094 0.2379 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.15 48.9 91.9 0.092 ? 17.3 4.1 ? 105403 ? ? 38.6
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.15 2.19 98.0 ? ? ? 3.1 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 113 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.9_1692
XDS data reduction .
Aimless data scaling .
PHASER phasing .