X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 290 0.1 M Tris-HCl, 2.0-1.8 M ammonium sulfate, 2%-5% v/v PPG P400
Unit Cell:
a: 88.017 Å b: 109.364 Å c: 57.029 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.16 Solvent Content: 43.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.9910 46.4480 38081 1909 98.9900 0.1865 0.2170 33.7460
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.990 50.000 99.000 0.120 ? 5.800 4.300 ? 38140 ? ? 26.510
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.990 2.020 90.700 ? ? ? 4.000 1722
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 23-ID-B 1.0332 APS 23-ID-B
Software
Software Name Purpose Version
PHENIX refinement 1.8.2_1309
HKL-2000 data collection .
SCALEPACK data scaling .
PDB_EXTRACT data extraction 3.15
DENZO data reduction .
PHENIX phasing .
Feedback Form