X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293.15 0.l M tri-sodium citrate pH 5.3-5.4, 0.05 M sodium thiocyanate, 29-32% PEG400, 2% (v/v) 2,5-hexanediol and 0.005 mM Compound 4e.
Unit Cell:
a: 39.369 Å b: 179.247 Å c: 140.066 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.57 Solvent Content: 52.15
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.900 33.706 39432 3713 99.27 0.1738 0.1963 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 33.71 99.3 0.080 ? 11.3 4.7 ? 39460 ? ? 36.7
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.94 99.6 ? ? 1.4 4.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON DIAMOND BEAMLINE I24 0.96857 Diamond I24
Software
Software Name Purpose Version
PHENIX refinement (1.12rc2_2821: ???)
XDS data reduction .
Aimless data scaling .
PHASER phasing .
Feedback Form