X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.0 277 26 - 30 % (v/v) PEG 400, 0.1 M sodium citrate pH 5.0 and 75 mM sodium chloride or sodium acetate. GDP-mannose was soaked in at 20mM overnight.
Unit Cell:
a: 45.319 Å b: 101.694 Å c: 180.192 Å α: 89.86° β: 90.07° γ: 90.11°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.80 Solvent Content: 56.11
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.600 44.328 36015 1950 96.59 0.2597 0.3127 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.6 45.3 96.8 ? ? 3.8 1.8 ? 36110 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.60 3.76 97.2 ? ? 0.6 1.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 83 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 2 0.9800 SOLEIL PROXIMA 2
Software
Software Name Purpose Version
PHENIX refinement (1.11.1_2575: ???)
XDS data reduction .
Aimless data scaling .
PHASER phasing .