Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Documentation
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
5NZT
pdb_00005nzt
10.2210/pdb5nzt/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
The structure of the COPI coat leaf
Specimen Preperation
Sample Aggregation State
3D ARRAY
Vitrification Instrument
HOMEMADE PLUNGER
Cryogen Name
ETHANE
Sample Vitrification Details
The sample was applied onto glow-discharged (30 sec, 20 mA) C-flat (Protochips Inc.) multihole grids. The grids were blotted from the back side for 11 seconds at room temperature in a chamber at 85% humidity and plunge-frozen into liquid ethane using a manual plunger.
3D Reconstruction
Reconstruction Method
SUBTOMOGRAM AVERAGING
Number of Particles
2547
Reported Resolution (Å)
17
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
Cross-correlation coefficient
Overall B Value
?
Fitting Procedure
?
Details
?
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å
2
)
2
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
2500
Maximum Defocus (nm)
5000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
?
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Tomographic tilt series were acquired with the dose-symmetric tilt-scheme (Hagen et al., J Struct Biol. 2017)
Imaging Experiment
Task
Software Package
Version
VOLUME SELECTION
Amira
?
IMAGE ACQUISITION
SerialEM
?
CTF CORRECTION
CTFFIND
4
MODEL FITTING
UCSF Chimera
1.11
RECONSTRUCTION
TOM Toolbox
?
VOLUME SELECTION
TOM Toolbox
?
CTF CORRECTION
IMOD
?
RECONSTRUCTION
AV3
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING ONLY
CTF-determination for each individual tilt image was performed using CTFFIND4. Strip-based CTF-correction and tomogram reconstruction was performed in Imod.
Feedback
Feedback Form
Name
Email
Institute
Feedback
Submit