Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
5NG5
pdb_00005ng5
10.2210/pdb5ng5/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
AcrABTolC in apo state
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
a 3ul aliquot at a concentration of 2 mg per ml was applied onto glow-discharged holey carbon grid (Quantifoil Au R1.21.3, 300 mesh)
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
13544
Reported Resolution (Å)
6.5
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Cross-correlation coefficient
Overall B Value
?
Fitting Procedure
?
Details
Crystal structures were rigid-body fit into the density map and model optimization was then carried out with Phenix real-space refine. Due to the weaker resolution, stronger stereochemical and secondary structure restraints were used to ensure that alpha-helices and beta-sheets did not deviate far from their expected geometry. Manual adjustments were kept to a minimum to reduce human bias in the modeling procedure, with Coot only being used to fix obvious errors such as C-beta deviations. A final check of MolProbity and cross correlation was done to ensure model quality.
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
1
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
?
Maximum Defocus (nm)
?
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
?
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
?
Nominal Magnification
?
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
CTF CORRECTION
CTFFIND
4
MODEL FITTING
UCSF Chimera
?
INITIAL EULER ASSIGNMENT
EMAN
2.2
FINAL EULER ASSIGNMENT
RELION
2
MODEL REFINEMENT
PHENIX
?
MODEL REFINEMENT
Coot
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING ONLY
?