X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 291 Three single crystals appeared after one year and could be immediately fished. The drop contained a mixture of 0.8 ul of 35 mg/ml of MCR III Methanotorris formicicus and 0.8 ul of the reservoir solution containing 200 mM potassium bromide, 200 mM potassium thiocyanate, 100 mM Na cacodylate pH 6.5, 3% (w/v) PGA-LM, and 30% PEG 400 (v/v).
Unit Cell:
a: 127.699 Å b: 127.699 Å c: 160.376 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 2.75 Solvent Content: 55.34
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.80 39.85 37735 1898 99.88 0.1991 0.2208 61.19
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.80 48.13 99.9 0.188 ? 7.4 5.0 ? 37773 ? ? 62.56
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.80 2.95 100.0 ? ? 2.3 4.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X10SA 0.99998 SLS X10SA
Software
Software Name Purpose Version
BUSTER refinement 2.10.1
XDS data reduction .
SCALA data scaling 3.3.22
MOLREP phasing 11.0.05
Feedback Form
Name
Email
Institute
Feedback