X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 277 20 mM sodium dihydrogen phosphate ph 7.5, 350 mM NaCl, 27% PEG 8000
Unit Cell:
a: 70.344 Å b: 71.649 Å c: 72.538 Å α: 90.00° β: 100.48° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.7 Solvent Content: 53.7
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.290 43.577 85676 4285 96.46 0.1244 0.1421 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.29 43.577 96.3 ? ? 16.34 3.4 ? 85703 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.29 1.37 93.1 ? ? 2.36 3.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.979 ESRF ID29
Software
Software Name Purpose Version
PHENIX refinement (1.10.1_2155: ???)
Coot model building Punta Carretas 0.8-pre
XDS data scaling .
XDS data reduction .
PHASER phasing .