X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 THE PURIFIED PROTEIN WAS DISSOLVED IN 50 MM TRIS-HCL, PH 7.5 AND CONCENTRATED TO 11 MG/ML. 1 UL OF PROTEIN SOLUTION WAS EQUILIBRATED AGAINST 1 UL OF RESERVOIR SOLUTION CONTAINING 16-20% PEG3350, 100 MM MES PH 5.5 AND 50 MM ZNACETATE
Unit Cell:
a: 82.039 Å b: 82.039 Å c: 95.813 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 41 21 2
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.81
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? THROUGHOUT 1.64 58.03 37443 2793 98.90 0.17469 0.20705 19.46
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.64 95.79 98.9 0.065 ? 10.2 10.2 ? 40237 -3 ? 23.2
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.64 1.71 92.5 ? ? 5.82 6.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 1.03320 ESRF ID29
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
XDS data reduction .
XSCALE data scaling .
REFMAC phasing 5.2.0019
Feedback Form
Name
Email
Institute