X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 3.5 298 0.1M Citric acid, 25% PEG3350
Unit Cell:
a: 41.154 Å b: 44.657 Å c: 54.136 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 1.94 Solvent Content: 36.72
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD FREE R-VALUE 2.4 34.4490 7314 333 96.6700 0.1937 0.2464 21.4159
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.400 50.000 98.100 0.097 ? 15.600 5.800 ? 4158 ? ? 20.240
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.400 2.440 80.900 ? ? ? 3.100 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-BM 1.7712 APS 19-BM
Software
Software Name Purpose Version
PHENIX refinement dev_2386
SCALEPACK data scaling .
PDB_EXTRACT data extraction 3.20
HKL-3000 data reduction .
HKL-3000 phasing .
Feedback Form
Name
Email
Institute
Feedback