X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 291 0.1 M Bicine/Tris buffer pH8.5 including 10% (v/v) PEG 4000, 25% (v/v) ethylene glycol and 55mM D, L-lysine
Unit Cell:
a: 72.383 Å b: 114.366 Å c: 130.462 Å α: 90.00° β: 92.04° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 3.01 Solvent Content: 59.15
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.700 44.859 56890 2806 97.35 0.2252 0.2692 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.70 47.6 97.4 0.062 0.062 11.6 3.0 ? 56903 ? ? 52.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.70 2.77 99.3 ? ? 1.6 3.0 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 113 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.954 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.9_1692
XDS data reduction .
Aimless data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback