X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 298 0.2 M ammonium chloride, 0.025 M calcium chloride, 0.2 M Tris-HCl
Unit Cell:
a: 135.734 Å b: 199.019 Å c: 70.775 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 3.69 Solvent Content: 70.99
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT NONE 3.0510 38.1950 18347 918 98.1900 0.1829 0.2186 56.0700
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.05 50 99.78 ? ? 14.5 3.7 ? 18708 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.05 3.10 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL17U 0.979 SSRF BL17U
Software
Software Name Purpose Version
HKL-2000 data scaling .
PHENIX refinement 1.8.2_1309
PDB_EXTRACT data extraction 3.20
HKL-2000 data reduction .
PHENIX phasing .