X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 RATIO 1:1, 293K, HANGING DROP. RESERVOIR CONDITION: 0.2 M NACL, 30% (V/V) MPD AND 0.1 M SODIUM ACETATE PH 4.6
Unit Cell:
a: 117.942 Å b: 128.168 Å c: 98.260 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.41 Solvent Content: 49
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.90 98.26 111731 5861 99.96 0.20405 0.26937 21.142
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 47.04 100.0 0.08 ? 18.50 7.1 ? 117661 ? 0.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.93 100.0 ? 4.40 7.1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM30A ? ESRF BM30A
Software
Software Name Purpose Version
REFMAC refinement 5.8.0107
XDS data reduction .
Aimless data scaling .
PHASER phasing .