ELECTRON MICROSCOPY


Sample

FULL-LENGTH HUMAN P97 BOUND TO UPCDC30245 INHIBITOR

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details VITRIFICATION 1 -- CRYOGEN- ETHANE, HUMIDITY- 100, TEMPERATURE- 90.15, INSTRUMENT- FEI VITROBOT MARK IV, METHOD- BLOT FOR 2.5 SECONDS BEFORE PLUNGING.
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 40913
Reported Resolution (Å) 2.3
Resolution Method ?
Other Details N-TERMINAL RESIDUES 21-200 DISORDERED. LINKER CONNECTING RESIDUES 707 TO 728 IS NOT IN THE MODEL. SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-3295. (DEPOSITION ID: 14163).
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector Type GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å2) 40
Imaging Experiment
Date of Experiment 2015-02-16
Temprature (Kelvin)
Microscope Model FEI TITAN KRIOS
Minimum Defocus (nm) 700
Maximum Defocus (nm) 2500
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model .
Nominal Magnification 215000
Calibrated Magnification 78490
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details PARALLEL BEAM ILLUMINATION
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
? EACH PARTICLE