X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 10% PEG 4K, 20% Glycerol, 0.02M CA, pH 7.5 (MORPHEUS G7) [CA= carboxylic acid mix, buffer=MOPS/HEPES-Na]
Unit Cell:
a: 101.444 Å b: 139.592 Å c: 181.768 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 54.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.05 19.81 161545 8143 100.0 0.193 0.219 47.93
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.050 19.810 99.9 0.11800 ? 17.5000 14.20 ? 161660 ? ? 40.12
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.05 2.09 100.0 ? 1.200 14.30
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement .
Aimless data scaling 0.2.8
PDB_EXTRACT data extraction 3.15
XDS data scaling .
PHASER phasing .