X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 293 Zinc Chloride, Tris, PEG 6000
Unit Cell:
a: 64.110 Å b: 92.225 Å c: 64.937 Å α: 90.00° β: 96.34° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.44 Solvent Content: 49.54
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.50 64.54 24692 1328 99.59 0.23180 0.27520 59.041
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.5 64.54 99.6 0.077 ? 11.0 3.4 ? 26038 ? ? 38.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.5 2.6 97.9 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON BESSY BEAMLINE 14.1 1.2782 BESSY 14.1
Software
Software Name Purpose Version
REFMAC refinement 5.8.0073
XDS data reduction .
Aimless data scaling .
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback