X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 277 31 % PEG-4000, 0.09 M Mg-acetate
Unit Cell:
a: 104.813 Å b: 112.678 Å c: 39.865 Å α: 90.000° β: 92.560° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 4.69 Solvent Content: 73.79
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.5500 30.0000 14354 731 99.6800 0.1921 0.2335 32.4130
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.550 39.830 99.600 0.130 ? 9.300 4.400 ? 15087 ? ? 28.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.550 2.660 97.200 ? ? 2.200 4.100 1821
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-2 0.87260 ESRF ID23-2
Software
Software Name Purpose Version
Aimless data scaling 0.1.27
MOLREP phasing 11.0.05
REFMAC refinement 5.7.0029
PDB_EXTRACT data extraction 3.15
XDS data reduction .