X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 289 PEG 6000, Ammonium Acetate, Sodium Acetate, DTT
Unit Cell:
a: 219.050 Å b: 390.940 Å c: 278.080 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 5.53 Solvent Content: 77.76
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.7000 40.0000 122114 3691 96.4300 0.2012 0.2197 134.2200
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.400 195.470 89.300 ? 0.319 3.200 3.500 145314 145314 ? ? 59.190
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.400 3.580 55.400 ? 1.413 0.500 3.200 13052
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 23-ID-D 1.0332 APS 23-ID-D
Software
Software Name Purpose Version
BUSTER-TNT refinement BUSTER 2.10.2
SCALA data scaling 3.3.20
PDB_EXTRACT data extraction 3.15
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback