X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 291 PEG 4000, PEG 400, magnesium chloride, tris
Unit Cell:
a: 69.507 Å b: 104.973 Å c: 63.785 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.20 Solvent Content: 44.11
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.5000 25.0000 15278 819 96.0400 0.1915 0.2776 54.0360
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.500 30.000 96.000 0.134 ? 4.500 3.900 ? 16205 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.500 2.590 95.500 ? ? ? 3.500 1569
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSRRC BEAMLINE BL13B1 1 NSRRC BL13B1
Software
Software Name Purpose Version
SCALEPACK data scaling .
PHASER phasing .
REFMAC refinement 5.7.0029
PDB_EXTRACT data extraction 3.15