X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 ? 0.2 M AMMONIUM ACETATE, 0.1 M NA ACETATE AND 20% PEG4000 PH5.15, pH 7
Unit Cell:
a: 86.698 Å b: 86.698 Å c: 121.861 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 61 2 2
Crystal Properties:
Matthew's Coefficient: 2.27 Solvent Content: 47.01
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.201 47.312 25987 1310 99.97 0.1722 0.2180 44.71
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.20 47.31 100.0 0.14 ? 14.09 10 ? 25987 ? 1.8 38.34
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.20 2.33 100.0 ? 1.80 9.66
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-2 ? ESRF ID23-2
Software
Software Name Purpose Version
PHENIX refinement (PHENIX.REFINE)
XDS data reduction .
XSCALE data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback