4ZX8

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 298 40% (v/v) PEG 400, 0.1 M Tris pH 8.5, 0.2 M Li2SO4
Unit Cell:
a: 174.393 Å b: 177.470 Å c: 231.292 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.59 Solvent Content: 52.52
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.70 48.95 195615 9884 99.6 0.199 0.245 21.29
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.700 48.950 100.0 0.47000 ? 4.4000 5.000 ? 196372 ? ? 18.91
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.70 2.75 99.9 ? 1.700 4.80
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.8.4_1496
Blu-Ice data collection .
MOSFLM data reduction .
Aimless data scaling 0.3.8
PHASER phasing .
PDB_EXTRACT data extraction 3.15