X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.2 289 2 M sodium/potassium phosphate buffer, 0.1 M phosphate citrate buffer
Unit Cell:
a: 73.815 Å b: 74.032 Å c: 178.493 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.59 Solvent Content: 52.49
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 2.57 36.2400 30323 1627 99.0400 0.2113 0.2776 87.3200
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.570 50.000 99.800 0.091 ? 9.800 5.900 ? 32010 0 0 74.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.570 2.610 100.000 ? ? 2.15 6.000 1574
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-ID 0.9792 APS 19-ID
Software
Software Name Purpose Version
HKL-3000 data scaling .
REFMAC refinement 5.8.0073
PDB_EXTRACT data extraction 3.15
HKL-3000 data reduction .
HKL-3000 phasing .