X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.0 293 1.6M (NH4)2SO4, 18% GLYCEROL, 8 MM DTT, 100 MM NA-CITRATE, PH 5.0, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 293K
Unit Cell:
a: 75.418 Å b: 88.430 Å c: 152.744 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.66 Solvent Content: 53.80
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.64 45.88 59173 3155 99.9 0.203 0.222 30.03
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.640 50.000 99.0 0.08800 0.08300 33.7000 15.500 ? 59173 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.64 1.70 90.1 ? 0.53200 4.900 13.60 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X29A 1.075 NSLS X29A
Software
Software Name Purpose Version
HKL-2000 data reduction .
SCALA data scaling .
MOLREP phasing .
REFMAC refinement 5.6.0117
Feedback Form
Name
Email
Institute