Planned Maintenance: Some services may turn out to be unavailable from 15th January, 2026 to 16th January, 2026. We apologize for the inconvenience!

X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 0.1 M Tris pH 8, 40% PEG 300
Unit Cell:
a: 149.515 Å b: 149.515 Å c: 88.971 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32
Crystal Properties:
Matthew's Coefficient: 3.87 Solvent Content: 68.18
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.901 29.706 49207 2395 99.93 0.1969 0.2350 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.9 30.0 96.2 0.097 ? 8.1 1.5 ? 49296 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.9 3.0 95.3 ? ? 1.9 1.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.9_1692
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .