Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
4V7D
pdb_00004v7d
10.2210/pdb4v7d/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
Pre-translocation 70S ribosome with A/P*, P/E hybrid state tRNA and EF-G bound
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK II
Cryogen Name
ETHANE
Sample Vitrification Details
Freshly glow-disharged grids were loaded into an FEI Mark II Vitrobot and equilibrated to 95% relative humidity at 22 degrees Celsius. 2 microliters of sample was applied through the side port, blotted for 7 seconds with a positional offset of 2, and plunged into liquid ethane.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
85115
Reported Resolution (Å)
7.6
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement included data to 12 Angstrom resolution to limit FSC bias. See primary citation Supplementary Information for details. (Single particle details: Refinement and 3D classification performed by Frealign) (Single particle--Applied symmetry: C1)
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
Cross-correlation
Overall B Value
?
Fitting Procedure
?
Details
REFINEMENT PROTOCOL--rigid body
Data Acquisition
Detector Type
FEI FALCON I (4k x 4k)
Electron Dose (electrons/Å
2
)
30
Imaging Experiment
Date of Experiment
2012-11-02
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
1150
Maximum Defocus (nm)
6950
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
0.01
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
133333
Calibrated Magnification
134615
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
CTF CORRECTION
CTFFIND
3
MODEL FITTING
CNS
?
MODEL FITTING
UCSF Chimera
?
RECONSTRUCTION
EMAN
2
RECONSTRUCTION
FREALIGN
?
RECONSTRUCTION
IMAGIC
?
RECONSTRUCTION
RSAMPLE
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
.
CTFFIND3, FREALIGN per micrograph