ELECTRON MICROSCOPY
Sample
POINTER-SHAPED 3D DNA- ORIGAMI OBJECT
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK III
Cryogen Name
ETHANE
Sample Vitrification Details
LIQUID ETHANE
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
28502
Reported Resolution (Å)
11.5
Resolution Method
FSC 0.143 CUT-OFF
Other Details
TWO MODELS WERE REFINED INDEPENDENTLY TO PREVENT OVERFITTING THROUGH GOLD-STANDARD FOURIER-SHELL CORRELATIONS. THERE IS A MISSING COVALENT BOND BETWEEN THE LAST BASE OF THIS PDB FILE AND THE FIRST ONE IN PDB ENTRY 2YMG. IN ADDITION THERE IS A COVALENT BOND BETWEEN THE FIRST BASE IN THIS FILE AND THE LAST IN 2YMG GIVING A CIRCULAR MOLECULE. IN TOTAL THERE ARE FIVE PDB FILES. SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2210.(DEPOSITION ID: 11146).
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
RECIPROCAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
METHOD--MOLECULAR DYNAMICS FLEXIBLE FITTING REFINEMENT PROTOCOL--THEORETICAL
Data Acquisition
Detector Type
FEI FALCON I (4k x 4k)
Electron Dose (electrons/Å
2
)
10
Imaging Experiment
Date of Experiment
2012-04-01
Temprature (Kelvin)
Microscope Model
FEI POLARA 300
Minimum Defocus (nm)
890
Maximum Defocus (nm)
4460
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
.
Nominal Magnification
31000
Calibrated Magnification
39436
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
CTF CORRECTION
CTFFIND
3
RECONSTRUCTION
RELION
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
.
WIENER FILTER (RELION)