X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.7 ? 12.5 % (W/V) PEG 1000, 12.5% (W/V) PEG 3350, 12.5% (V/V) MPD, 0.1 M TRIZMA-BICINE, PH 8.7 AND 0.01 M CDCL2
Unit Cell:
a: 39.737 Å b: 59.292 Å c: 62.468 Å α: 106.86° β: 104.90° γ: 93.37°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.07 Solvent Content: 40.59
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.55 19.73 73160 ? 96.6 ? 0.214 16.53
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.55 19.73 96.6 0.13 ? 8.60 3.4 ? 73161 ? 2.0 11.35
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.55 1.61 94.8 ? 1.90 3.4
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 193 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 ? Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement (PHENIX.REFINE)
XDS data reduction .
Aimless data scaling .
PHENIX phasing .