X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 293 0.2 M Mg Acetate, 4% DMSO, 20% PEG3350, 0.1 M Hepes, pH 6.5
Unit Cell:
a: 59.834 Å b: 109.661 Å c: 102.099 Å α: 90.00° β: 91.77° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.34 Solvent Content: 47.34
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.80 31.37 119224 5992 98.0 0.174 0.209 41.12
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.800 50.000 98.3 0.05300 ? 15.2000 6.700 ? 119276 ? ? 25.49
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.80 1.86 96.3 ? ? 6.10
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.95364 Australian Synchrotron MX1
Software
Software Name Purpose Version
PHENIX refinement (PHENIX.REFINE: 1.8.4_1496)
Blu-Ice data collection .
SCALEPACK data scaling .
PHASER phasing .
Coot model building .
PDB_EXTRACT data extraction 3.14