X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.3 293 22% PEG8000, 1% MPD, 5MM DITHIOTHREITOL, 100MM IMIDAZOLE, PH 6.3, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 49.801 Å b: 77.169 Å c: 117.741 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 2 21 21
Crystal Properties:
Matthew's Coefficient: 2.47 Solvent Content: 50.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.68 38.02 13058 642 98.1 0.228 0.287 61.24
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.680 46.805 98.1 0.06000 ? 19.8000 6.000 ? 13058 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.68 2.78 98.1 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 ? Australian Synchrotron MX2
Software
Software Name Purpose Version
PHASER phasing .
PHENIX refinement (PHENIX.REFINE: 1.8_1069)
XDS data reduction .
XDS data scaling .