X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 291 0.1 M HEPES, 25% w/v PEG3350, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K
Unit Cell:
a: 78.330 Å b: 78.330 Å c: 202.991 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32
Crystal Properties:
Matthew's Coefficient: 3.29 Solvent Content: 62.61
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.105 24.859 73531 3895 95.95 0.21332 0.25771 26.923
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.105 24.859 95.9 0.16 0.16 7.2 3.58 84193 80742 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.105 2.15 93.6 ? ? 2.2 3.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL7-1 0.97 SSRL BL7-1
Software
Software Name Purpose Version
Blu-Ice data collection .
PHASER phasing .
REFMAC refinement 5.5.0072
iMOSFLM data reduction .
SCALA data scaling .