X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 298 22% (v/v) PEG 8000, 10* (v/v) glycerol, 0.1 M Tris pH 8.5, 0.2 M MgCl2, vapor diffusion, hanging drop, temperature 298K
Unit Cell:
a: 75.222 Å b: 109.593 Å c: 118.698 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.34 Solvent Content: 47.47
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.1000 30.5130 57571 2915 99.3700 0.1832 0.2219 31.9100
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.100 46.590 99.500 0.201 ? 12.600 11.200 ? 57652 ? ? 25.660
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.100 2.160 98.900 ? ? 2.200 11.400 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.9537 Australian Synchrotron MX1
Software
Software Name Purpose Version
MOSFLM data reduction .
Aimless data scaling 0.2.4
PHENIX refinement 1.8.4_1496
PDB_EXTRACT data extraction 3.15
GDA data collection .
SCALA data scaling .
PHASER phasing .