X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 294 100 MM MES, 200 MM CALCIUM ACETATE, 20% PEG 8000, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 294K
Unit Cell:
a: 38.070 Å b: 53.864 Å c: 53.977 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.05 Solvent Content: 40.00
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.40 31.089 22271 1141 99.38 0.1503 0.1887 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.4 50 99.38 ? 0.062 15 5.9 ? 22271 0 0 19.9
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.40 1.45 99.8 ? 0.425 3.29 5.8 2181
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-D 0.97872 APS 21-ID-D
Software
Software Name Purpose Version
HKL-2000 data collection .
PHENIX model building (phenix.refine: 1.9_1692)
PHENIX refinement (phenix.refine: 1.9_1692)
HKL-2000 data reduction .
HKL-2000 data scaling .
PHENIX phasing 1.9_1692