4QZI

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293 12-17% PEG4000, 9-12% isopropanol, 100 mM sodium acetate, 100 mM HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 57.700 Å b: 71.523 Å c: 113.035 Å α: 90.00° β: 94.17° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.25 Solvent Content: 45.31
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.65 22.42 13373 660 99.52 0.1862 0.2025 77.23
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.65 45 99.6 0.063 ? 13.6 4.1 ? 13390 ? ? 87.56
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.65 2.79 100 ? ? 2.1 4.2 1937
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 0.972500 ESRF ID23-1
Software
Software Name Purpose Version
DNA data collection .
PHASER phasing .
BUSTER refinement 2.10.1
XDS data reduction .
SCALA data scaling .