X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 293 0.01M magnesium sulphate, 0.05M sodium cacodylate, 1.8M lithium sulphate, pH 6.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 44.393 Å b: 44.393 Å c: 46.254 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 3.04 Solvent Content: 59.55
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION P-SAD THROUGHOUT 1.400 25.974 9567 479 99.99 0.1411 0.1593 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.4 46.25 100 0.06 0.06 19.3 12.1 9608 9608 0.0 0.0 22.9
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.40 1.48 100 ? 0.1715 2.0 12.2 1347
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON DIAMOND BEAMLINE I24 0.9686 Diamond I24
Software
Software Name Purpose Version
GDA data collection .
PHENIX model building (phenix.refine: 1.9_1692)
PHENIX refinement (phenix.refine: 1.9_1692)
XDS data reduction .
XSCALE data scaling .
PHENIX phasing 1.9_1692
Feedback Form